dc.identifier.citation | Свириденко, И.И. Расчетная оценка продолжительности эффективной работы автономной СПОТ при сравнении теплоотвода к воде и к атмосферному воздуху / И.И. Свириденко // Вестник ЮУрГУ. Серия «Энергетика». – 2016. – Т. 16, № 3. – С. 5–14. DOI: 10.14529/power160301 Sviridenko I.I. Estimated Duration of Effective Operation of Autonomous Passive Residual Heat Removal System (PRHRS) at Comparing Heat Removal to Cooling Water vs Ambient Air. Bulletin of the South Ural State University. Ser. Power Engineering, 2016, vol. 16, no. 3, pp. 5–14. (in Russ.) DOI: 10.14529/power160301 | ru_RU |
dc.identifier.issn | 2409-1057 | |
dc.identifier.uri | http://dspace.susu.ru/xmlui/handle/0001.74/30392 | |
dc.description | Свириденко Игорь Иванович, канд. техн. наук, доцент, кафедра «Энергоустановки морских судов и сооружений» института Кораблестроения и морского транспорта, Севастопольский государственный университет, г. Севастополь; i.sviridenko@mail.ru. I.I. Sviridenko, i.sviridenko@mail.ru Sevastopol State University, Sevastopol, Russian Federation | ru_RU |
dc.description.abstract | Рассмотрена схема и принцип действия автономной термосифонной системы пассивного отвода остаточного тепловыделения (СПОТ) от первого контура реакторной установки АЭС с ВВЭР в условиях запроектной аварии с полным длительным обесточиванием, потерей питательной воды и течами первого контура. Приведены особенности организации отвода остаточного тепловыделения РУ к воде или к атмосферному воздуху с помощью автономной термосифонной СПОТ. Представлены результаты расчетной оценки продолжительности эффективной работы автономной СПОТ при теплоотводе к воде и к ат- мосферному воздуху, при которой обеспечивается автономность реакторной установки и ее безопасное состояние. Результаты получены методом расчетного моделирования с использованием теплогидравлического кода RELAP5/MOD3.4. Дана сравнительная оценка полученных результатов. Проанализированы преимущества и недостатки использования воды и воздуха в качестве конечного поглотителя автономной термосифонной СПОТ. The article presents the layout and operation principles of an autonomous thermosiphon-based passive residual heat removal system (PRHRS) from the primary circuit of the nuclear power plant with VVER reactor under beyond-design accident conditions with complete long-term blackout, loss of feed water and primary LOCAs. Peculiarities of residual heat removal to water or ambient air by autonomous thermosiphon PRHRS are presented. The results of the analytical evaluation and estimated duration of effective operation of the autonomous PRHRS removing residual heat to water and air and providing a safe stable reactor condition are shown. The results were received based on numerical simulation using RELAP5 / MOD3.4 thermal-hydraulic code. The comparative evaluation of the results is made. The advantages and disadvantages of the use of water vs air as the final heat absorber are analyzed. | ru_RU |
dc.language.iso | other | ru_RU |
dc.publisher | Издательский центр ЮУрГУ | ru_RU |
dc.relation.ispartof | Вестник ЮУрГУ. Серия Энергетика | ru |
dc.relation.ispartof | Vestnik Ûžno-Ural’skogo gosudarstvennogo universiteta. Seriâ Ènergetika | en |
dc.relation.ispartof | Bulletin of SUSU | en |
dc.relation.ispartofseries | Энергетика;Т. 16 | |
dc.subject | УДК 621.039.587 | ru_RU |
dc.subject | АЭС с ВВЭР | ru_RU |
dc.subject | безопасность | ru_RU |
dc.subject | пассивный теплоотвод | ru_RU |
dc.subject | конечный поглотитель | ru_RU |
dc.subject | СПОТ | ru_RU |
dc.subject | термосифонное теплообменное оборудование | ru_RU |
dc.subject | nuclear power plants with VVER | ru_RU |
dc.subject | safety | ru_RU |
dc.subject | passive heatsink | ru_RU |
dc.subject | final heat absorber | ru_RU |
dc.subject | PRHRS | ru_RU |
dc.subject | thermosiphon heat transfer equipment | ru_RU |
dc.title | Расчетная оценка продолжительности эффективной работы автономной СПОТ при сравнении теплоотвода к воде и к атмосферному воздуху | ru_RU |
dc.title.alternative | Estimated Duration of Effective Operation of Autonomous Passive Residual Heat Removal System (PRHRS) at Comparing Heat Removal to Cooling Water vs Ambient Air | ru_RU |
dc.type | Article | ru_RU |
dc.identifier.doi | DOI: 10.14529/power160301 |