Репозиторий Dspace

Расчетная оценка продолжительности эффективной работы автономной СПОТ при сравнении теплоотвода к воде и к атмосферному воздуху

Показать сокращенную информацию

dc.contributor.author Свириденко, И.И.
dc.contributor.author Sviridenko, I.I.
dc.date.accessioned 2020-10-21T04:51:09Z
dc.date.available 2020-10-21T04:51:09Z
dc.date.issued 2016
dc.identifier.citation Свириденко, И.И. Расчетная оценка продолжительности эффективной работы автономной СПОТ при сравнении теплоотвода к воде и к атмосферному воздуху / И.И. Свириденко // Вестник ЮУрГУ. Серия «Энергетика». – 2016. – Т. 16, № 3. – С. 5–14. DOI: 10.14529/power160301 Sviridenko I.I. Estimated Duration of Effective Operation of Autonomous Passive Residual Heat Removal System (PRHRS) at Comparing Heat Removal to Cooling Water vs Ambient Air. Bulletin of the South Ural State University. Ser. Power Engineering, 2016, vol. 16, no. 3, pp. 5–14. (in Russ.) DOI: 10.14529/power160301 ru_RU
dc.identifier.issn 2409-1057
dc.identifier.uri http://dspace.susu.ru/xmlui/handle/0001.74/30392
dc.description Свириденко Игорь Иванович, канд. техн. наук, доцент, кафедра «Энергоустановки морских судов и сооружений» института Кораблестроения и морского транспорта, Севастопольский государственный университет, г. Севастополь; i.sviridenko@mail.ru. I.I. Sviridenko, i.sviridenko@mail.ru Sevastopol State University, Sevastopol, Russian Federation ru_RU
dc.description.abstract Рассмотрена схема и принцип действия автономной термосифонной системы пассивного отвода остаточного тепловыделения (СПОТ) от первого контура реакторной установки АЭС с ВВЭР в условиях запроектной аварии с полным длительным обесточиванием, потерей питательной воды и течами первого контура. Приведены особенности организации отвода остаточного тепловыделения РУ к воде или к атмосферному воздуху с помощью автономной термосифонной СПОТ. Представлены результаты расчетной оценки продолжительности эффективной работы автономной СПОТ при теплоотводе к воде и к ат- мосферному воздуху, при которой обеспечивается автономность реакторной установки и ее безопасное состояние. Результаты получены методом расчетного моделирования с использованием теплогидравлического кода RELAP5/MOD3.4. Дана сравнительная оценка полученных результатов. Проанализированы преимущества и недостатки использования воды и воздуха в качестве конечного поглотителя автономной термосифонной СПОТ. The article presents the layout and operation principles of an autonomous thermosiphon-based passive residual heat removal system (PRHRS) from the primary circuit of the nuclear power plant with VVER reactor under beyond-design accident conditions with complete long-term blackout, loss of feed water and primary LOCAs. Peculiarities of residual heat removal to water or ambient air by autonomous thermosiphon PRHRS are presented. The results of the analytical evaluation and estimated duration of effective operation of the autonomous PRHRS removing residual heat to water and air and providing a safe stable reactor condition are shown. The results were received based on numerical simulation using RELAP5 / MOD3.4 thermal-hydraulic code. The comparative evaluation of the results is made. The advantages and disadvantages of the use of water vs air as the final heat absorber are analyzed. ru_RU
dc.language.iso other ru_RU
dc.publisher Издательский центр ЮУрГУ ru_RU
dc.relation.ispartof Вестник ЮУрГУ. Серия Энергетика ru
dc.relation.ispartof Vestnik Ûžno-Ural’skogo gosudarstvennogo universiteta. Seriâ Ènergetika en
dc.relation.ispartof Bulletin of SUSU en
dc.relation.ispartofseries Энергетика;Т. 16
dc.subject УДК 621.039.587 ru_RU
dc.subject АЭС с ВВЭР ru_RU
dc.subject безопасность ru_RU
dc.subject пассивный теплоотвод ru_RU
dc.subject конечный поглотитель ru_RU
dc.subject СПОТ ru_RU
dc.subject термосифонное теплообменное оборудование ru_RU
dc.subject nuclear power plants with VVER ru_RU
dc.subject safety ru_RU
dc.subject passive heatsink ru_RU
dc.subject final heat absorber ru_RU
dc.subject PRHRS ru_RU
dc.subject thermosiphon heat transfer equipment ru_RU
dc.title Расчетная оценка продолжительности эффективной работы автономной СПОТ при сравнении теплоотвода к воде и к атмосферному воздуху ru_RU
dc.title.alternative Estimated Duration of Effective Operation of Autonomous Passive Residual Heat Removal System (PRHRS) at Comparing Heat Removal to Cooling Water vs Ambient Air ru_RU
dc.type Article ru_RU
dc.identifier.doi DOI: 10.14529/power160301