Аннотации:
Derivation of dynamic mathematical model for steam accumulator, designed to smooth the peaks caused by nonuniform operation of industrial steam sources and consumers, is considered. The results of model testing over the data provided by steam supply system of metal manufacturing enterprise are provided. © 2010 Pleiades Publishing, Ltd.