Показать сокращенную информацию
dc.contributor.author | Егоров, И. С. | |
dc.contributor.author | Гольдштейн, М. Е. | |
dc.contributor.author | Egorov, I. S. | |
dc.contributor.author | Goldstein, M. E. | |
dc.date.accessioned | 2016-08-19T09:15:07Z | |
dc.date.available | 2016-08-19T09:15:07Z | |
dc.date.issued | 2015 | |
dc.identifier.citation | Егоров, И. С. Параметры элементов энергоблока, включающего синхронный генератор с нерегулируемым возбуждением и объединенный регулятор потоков мощности / И. С. Егоров, М. Е. Гольдштейн // Вестник ЮУрГУ. Серия Энергетика.- 2015.- Т. 15. № 4.- С. 26-31.- Библиогр.: с. 30 (9 назв.) | ru_RU |
dc.identifier.issn | 1990-8512 | |
dc.identifier.issn | 2409-1057 | |
dc.identifier.uri | http://dspace.susu.ac.ru/xmlui/handle/0001.74/7286 | |
dc.description | Егоров Иван Сергеевич, аспирант кафедры «Электрические станции, сети и системы», Южно-Уральский государственный университет, г. Челябинск; egorovis@susu.ac.ru. Гольдштейн Михаил Ефимович, канд. техн. наук., профессор, профессор кафедры «Электрические станции, сети и системы», Южно-Уральский государственный университет, г. Челябинск; goldshteinme@susu.ac.ru. I.S. Egorov, egorovis@susu.ac.ru, M.E. Goldshtein, goldshteinme@susu.ac.ru South Ural State University, Chelyabinsk, Russian Federation | ru_RU |
dc.description.abstract | По результатам исследований на имитационной модели в среде MATLAB Simulink определено распределение потоков мощности в энергоблоке, включающем синхронный генератор с нерегулируемым возбуждением и объединенный регулятор потока мощности (ОРПМ). Получены взаимосвязи параметров основного оборудования объединенного регулятора потока мощности, а также параметров режима его элементов и нормируемого диапазона изменения режимов энергосистемы. Using the software package MATLAB Simulink the simulation model “synchronous generator with fixed excitation – unified power flow controller – the external network of infinite power” has been developed. According to the results of research work, was obtained the power flow in the power unit that contains a synchronous generator with fixed excitation and unified power flow controller (UPFC). On the basis of the data obtained to construct the region of possible values of active power delivered power unit and the corresponding angles between the vectors of power unit voltage and voltage of the system. The methods of determining the parameters of the main equipment of the reporting unit was shown. Has been obtained the dependence of these parameters of main equipment of the unified power flow controller, as well as the mode parameters of its elements and the rated range of variation of the power system conditions. The results of the research can be applied in determining the appropriateness of the considered unit. | ru_RU |
dc.language.iso | other | ru_RU |
dc.publisher | Издательский центр ЮУрГУ | ru_RU |
dc.relation.ispartof | Вестник ЮУрГУ. Серия Энергетика | ru |
dc.relation.ispartof | Vestnik Ûžno-Ural’skogo gosudarstvennogo universiteta. Seriâ Ènergetika | en |
dc.relation.ispartof | Bulletin of SUSU | en |
dc.relation.ispartofseries | Энергетика;Том 15 | |
dc.subject | мощность | ru_RU |
dc.subject | синхронный генератор | ru_RU |
dc.subject | объединенный регулятор потоков мощности | ru_RU |
dc.subject | power flow | ru_RU |
dc.subject | synchronous generator | ru_RU |
dc.subject | unified power flow controller | ru_RU |
dc.subject | УДК 621.313.322 | ru_RU |
dc.subject | УДК 621.31 | ru_RU |
dc.subject | ГРНТИ 44.29 | ru_RU |
dc.title | Параметры элементов энергоблока, включающего синхронный генератор с нерегулируемым возбуждением и объединенный регулятор потоков мощности | ru_RU |
dc.title.alternative | Parameters of the elements of power unit, that contains a synchronous generator with fixed excitation and unified power flow controller | ru_RU |
dc.type | Article | ru_RU |