Репозиторий Dspace

Системная модель контроля и диагностики пожарной защиты силовой установки летательного аппарата

Показать сокращенную информацию

dc.contributor.author Куликов, Г.Г.
dc.contributor.author Кулбаев, Б.Р.
dc.contributor.author Kulikov, G.G.
dc.contributor.author Kulbaev, B.R.
dc.date.accessioned 2021-06-23T11:04:15Z
dc.date.available 2021-06-23T11:04:15Z
dc.date.issued 2019
dc.identifier.citation Куликов, Г.Г. Системная модель контроля и диагностики пожарной защиты силовой установки летательного аппарата / Г.Г. Куликов, Б.Р. Кулбаев // Вестник ЮУрГУ. Серия «Компьютерные технологии, управление, радиоэлектроника». - 2019. - Т. 19, № 2. - С. 145-152. DOI: 10.14529/ctcr190213. Kulikov G.G., Kulbaev B.R. System Model of Monitoring and Diagnostics Fire Protection of Aircraft Powerplant. Bulletin of the South Ural State University. Ser. Computer Technologies, Automatic Control, Radio Electronics, 2019, vol. 19, no. 2, pp. 145-152. (in Russ.) DOI: 10.14529/ctcr190213 ru_RU
dc.identifier.issn 2409-6571
dc.identifier.uri http://dspace.susu.ru/xmlui/handle/0001.74/40209
dc.description Куликов Геннадий Григорьевич, д-р техн. наук, профессор, Уфимский государственный авиационный технический университет, г. Уфа; gennadyg_98@yahoo.com. Кулбаев Булат Русланович, аспирант, Уфимский государственный авиационный технический университет, г. Уфа; bulat-kulbaev@rambler.ru. G.G. Kulikov, gennadyg_98@yahoo.com, B.R. Kulbaev, bulat-kulbaev@rambler.ru Ufa State Aviation Technical University, Ufa, Russian Federation ru_RU
dc.description.abstract Проблема пожарной защиты летательного аппарата, где наиболее энергонапряженным объектом является силовая установка, существует давно и продолжает быть актуальной и в настоящее время ввиду катастрофических последствий возникновения пожара на борту. В статье рассматриваются основные элементы системы пожарной защиты силовой установки в составе летательного аппарата. Описываются структурно-логическая модель работы блока пожарной защиты и принцип работы сигнализатора пожара пневматического типа, которые являются ключевыми элементами системы обеспечения безопасности эксплуатации летательного аппарата. Предлагается проводить системное моделирование процесса перехода силовой установки из нормального состояния в критическое состояние - пожар - на основе анализа законов сохранения и перехода различных видов энергии при пожаре. Отмечается, что разработаны и находят широкое применение методы и модели процессов горения различных материалов, реализованных в виде пакетов прикладных программ. Однако необходимым условием применения указанных пакетов является формализация предметной постановки задачи и задание ее исходных условий. Приводится методика построения структуры нестационарной модели пожара в отсеке силовой установки. Представлен эффективный инструмент при проведении испытаний системы пожарной защиты - комплексный стенд контроля и диагностики, который позволяет моделировать в квазистатическом режиме как процессы нормального функционирования системы, так и отказные ситуации. Приводятся результаты анализа процессов, полученных при испытаниях системы пожарной защиты силовой установки на комплексном полунатурном стенде. Среди преимуществ применения полунатурного стенда авторы выделяют значительное сокращение объема и стоимости натурных испытаний вновь разрабатываемых систем. Результаты работы могут быть использованы для разработки бортовой динамической модели распространения пожара в отсеке силовой установки для перспективной интеллектуальной системы пожаротушения. The problem of fire protection of aircraft, where the power plant is the most energy-intensive object, has existed for a long time and continues to be relevant in the present day due to the disastrous consequences of a fire on board. The article discusses the main elements of the fire protection system of the power plant as part of the aircraft. It describes the structural and logical model of the fire protection unit and the principle of operation of the pneumatic type fire detector, which are key elements of the safety system of the aircraft. It is proposed to carry out system modeling of the process of transition of a power plant from a normal state to a critical state - a fire, based on an analysis of the laws of conservation and transition of various types of energy during a fire. It is noted that the methods and models of the combustion processes of various materials, implemented in the form of application software packages, have been developed and are widely used. However, a necessary condition for the application of these packages is the formalization of the objective formulation of the problem and the setting of its initial conditions. A method for constructing the structure of a non-stationary model of a fire in a power plant compartment is given. An effective tool for testing the fire protection system is presented - a comprehensive monitoring and diagnostics bench, which allows simulating both processes of normal system operation and failure situations in a quasistatic mode. The results of the analysis of the processes obtained during testing of the fire protection system of a power plant on a complex semi-natural stand are presented. Among the advantages of using a semi-natural stand, the authors distinguish a significant reduction in the volume and cost of field tests of newly developed systems. The results of the work can be used to develop an on-board dynamic model of the spread of fire in the power plant compartment for a promising intelligent fire extinguishing system. ru_RU
dc.publisher Издательский центр ЮУрГУ ru_RU
dc.relation.ispartof Вестник ЮУрГУ. Серия Компьютерные технологии, управление, радиоэлектроника ru
dc.relation.ispartof Vestnik Yuzhno-Ural'skogo Gosudarstvennogo Universiteta. Seriya Kompjuternye tekhnologii, upravlenie, radioelektronika en
dc.relation.ispartof Bulletin of SUSU. Ser. Computer Technologies, Automatic Control, Radio Electronics en
dc.relation.ispartofseries Компьютерные технологии, управление, радиоэлектроника;Том 19
dc.subject УДК 629.7.067.8 ru_RU
dc.subject система пожарной защиты ru_RU
dc.subject пожар силовой установки ru_RU
dc.subject сигнализатор пожара ru_RU
dc.subject методология IDEF0 ru_RU
dc.subject модель пожара ru_RU
dc.subject стенд контроля и диагностики ru_RU
dc.subject fire protection system ru_RU
dc.subject power plant fire ru_RU
dc.subject fire detector ru_RU
dc.subject IDEF0 methodology ru_RU
dc.subject fire model ru_RU
dc.subject monitoring and diagnostics stand ru_RU
dc.title Системная модель контроля и диагностики пожарной защиты силовой установки летательного аппарата ru_RU
dc.title.alternative System Model of Monitoring and Diagnostics Fire Protection of Aircraft Powerplant ru_RU
dc.type Article ru_RU
dc.identifier.doi DOI: 10.14529/ctcr190213