dc.identifier.citation | Валеев, Р. Г. Концепция построения защиты электрических сетей напряжением 380 В от однофазных коротких замыканий / Р. Г. Валеев // Вестник ЮУрГУ. Серия Энергетика.- 2013.- Т. 13. № 1.- С. 30-34.- Библиогр.: с. 32-33 (15 назв.) | ru_RU |
dc.identifier.issn | 1990-8512 | |
dc.identifier.uri | http://dspace.susu.ac.ru/xmlui/handle/0001.74/4840 | |
dc.description | Валеев Рустам Галимянович, ассистент, кафедра «Системы электроснабжения», Южно-Уральский государственный университет, г. Челябинск, valeevrustam@mail.ru. R.G. Valeev, South Ural State University, Chelyabinsk, Russian Federation, valeevrustam@mail.ru | ru_RU |
dc.description.abstract | Предметом исследования данной работы является повышение уровня электробезопасности в электрических сетях напряжением 380 В с глухозаземленной нейтралью типа TN-C при однофазных коротких замыканиях на нулевой проводник и связанные с ним металлические конструкции. Согласно анализу аварийной статистики воздушные линии с неизолированными проводами являются наименее надежным элементом электрической сети – в 62 % случаев повреждения на них являются опасными для жизни людей и животных. В статье приведен краткий обзор литературы и обоснована актуальность разработки методики расчета, выбора и расстановки плавких предохранителей и автоматических выключателей по длине защищаемой линии, которые обеспечили бы 100%-ную зону ее защиты. Рассматриваемая в статье концепция построения защиты электрических сетей напряжением 380 В с глухозаземленной нейтралью заключается в секционировании по длине воздушной линии плавкими предохранителями и автоматическими выключателями. Концепция построения показана на примере защиты ВЛ-0,38 кВ длиной 500 м и сечением проводов 35 мм2, которая питается от трансформатора номинальной мощностью 160 кВА со схемой соединения обмоток Y/YН и защищается плавкими предохранителями с разными номинальными токами. Приведены графические зависимости, такие как изменение величины коэффициента чувствительности по длине линии, изменение зоны защиты в зависимости от тока плавкой вставки предохранителя для различных параметров электрической сети и др. Эти зависимости позволяют определить место установки плавких предохранителей или автоматических выключателей, обеспечивая отсутствие зон несрабатывания защит при времени срабатывания не более 5 с. Результаты исследований предполагается использовать для построения защиты как простых магистральных, так и разветвленных с отпайками широко применяемых воздушных линий напряжением 380 В. The subject of study of this work is to improve electrical safety in networks 380V neutral to earth type TN-C single-phase short-circuit on the neutral conductor and the associated metal structures. According to the analysis of accident statistics overhead lines with bare wires are the least reliable element of the electric network – 62 % of the damage they are dangerous to people and animals. This article is a brief review of the literature and the urgency of the development of methods of calculation, selection and placement of fuses and circuit breakers along the protected line, which would provide 100 % of the area to protect it. Considered in the design concept of the article protect electrical grids of 380 neutral to earth is the partitioning along the overhead lines fuses and circuit breakers. The concept of construction is shown by the example of security VL-0,38 kV 500 m long and a section of 35 mm square, which is powered by a transformer rated 160 kVA with a connection scheme Y/YH and protected by fuses with different rated currents. Graphic shows the dependence such as the change in the ratio of sensitivity to length line, changing the zone of protection, depending on the current fuse links for various electrical parameters, etc. These relationships allow us to determine the place of installation of fuses or circuit breakers to ensure the absence of a failure of protection zones in response time less than 5 seconds. Research results will be used to build the security of simple trunk and branches with a widely used taps overhead line voltage of 380 V. | ru_RU |
dc.language.iso | other | ru_RU |
dc.publisher | Издательский центр ЮУрГУ | ru_RU |
dc.relation.ispartof | Вестник ЮУрГУ. Серия Энергетика | ru |
dc.relation.ispartof | Vestnik Ûžno-Ural’skogo gosudarstvennogo universiteta. Seriâ Ènergetika | en |
dc.relation.ispartof | Bulletin of SUSU | en |
dc.relation.ispartofseries | Энергетика;Том 13 | |
dc.subject | электрическая сеть напряжением 380 В | ru_RU |
dc.subject | воздушная линия | ru_RU |
dc.subject | однофазные короткие замыкания | ru_RU |
dc.subject | электропоражения людей и животных | ru_RU |
dc.subject | защита от однофазных коротких замыканий | ru_RU |
dc.subject | electrical network voltage of 380 V | ru_RU |
dc.subject | overhead lines | ru_RU |
dc.subject | single-phase short-circuit | ru_RU |
dc.subject | electric shock of people and animals | ru_RU |
dc.subject | protection of single-phase short-circuit | ru_RU |
dc.subject | УДК 621.311.014.7 | ru_RU |
dc.subject | УДК 621.316.1.014.7 | ru_RU |
dc.subject | ГРНТИ 44.29 | ru_RU |
dc.title | Концепция построения защиты электрических сетей напряжением 380 В от однофазных коротких замыканий | ru_RU |
dc.title.alternative | The Concept of Building Protection of Electric Networks 380 V Single-Phase Short-Circuit | ru_RU |
dc.type | Article | ru_RU |